Characterization of the first operating period of a two-unit standby redundant system with three states of units
Applications of Mathematics, Tome 27 (1982) no. 5, pp. 341-351
Voir la notice de l'article provenant de la source Czech Digital Mathematics Library
A two-unit cold-standby redundant system with one repair facility is considered. Each unit can be in three states: good (I), degraded (II), and failed (III). We suppose that only the following state-transitions af a unit are possible: $I\rightarrow II, II\rightarrow III, II\rightarrow I, III\rightarrow I$. The paper is devoted to the problems which arise only provided that the units of the redundant system can be in more than two states (i.e. in operating and failed states). The following characteristics dealing with a single operating period of the system are studied under the condition that at its starting instant both units are new: the whole time of operation of units in state $I$ (or $II$), the whole time of repairs of units of the type $II\rightarrow I$ (or $III\rightarrow I$) and the number of finished repairs of units of the type $II\rightarrow I$ (or $III\rightarrow I$).
A two-unit cold-standby redundant system with one repair facility is considered. Each unit can be in three states: good (I), degraded (II), and failed (III). We suppose that only the following state-transitions af a unit are possible: $I\rightarrow II, II\rightarrow III, II\rightarrow I, III\rightarrow I$. The paper is devoted to the problems which arise only provided that the units of the redundant system can be in more than two states (i.e. in operating and failed states). The following characteristics dealing with a single operating period of the system are studied under the condition that at its starting instant both units are new: the whole time of operation of units in state $I$ (or $II$), the whole time of repairs of units of the type $II\rightarrow I$ (or $III\rightarrow I$) and the number of finished repairs of units of the type $II\rightarrow I$ (or $III\rightarrow I$).
DOI :
10.21136/AM.1982.103981
Classification :
60K10, 62N05, 90B25
Keywords: cold-standby redundant system
Keywords: cold-standby redundant system
Lešanovský, Antonín. Characterization of the first operating period of a two-unit standby redundant system with three states of units. Applications of Mathematics, Tome 27 (1982) no. 5, pp. 341-351. doi: 10.21136/AM.1982.103981
@article{10_21136_AM_1982_103981,
author = {Le\v{s}anovsk\'y, Anton{\'\i}n},
title = {Characterization of the first operating period of a two-unit standby redundant system with three states of units},
journal = {Applications of Mathematics},
pages = {341--351},
year = {1982},
volume = {27},
number = {5},
doi = {10.21136/AM.1982.103981},
mrnumber = {0674980},
zbl = {0504.60084},
language = {en},
url = {http://geodesic.mathdoc.fr/articles/10.21136/AM.1982.103981/}
}
TY - JOUR AU - Lešanovský, Antonín TI - Characterization of the first operating period of a two-unit standby redundant system with three states of units JO - Applications of Mathematics PY - 1982 SP - 341 EP - 351 VL - 27 IS - 5 UR - http://geodesic.mathdoc.fr/articles/10.21136/AM.1982.103981/ DO - 10.21136/AM.1982.103981 LA - en ID - 10_21136_AM_1982_103981 ER -
%0 Journal Article %A Lešanovský, Antonín %T Characterization of the first operating period of a two-unit standby redundant system with three states of units %J Applications of Mathematics %D 1982 %P 341-351 %V 27 %N 5 %U http://geodesic.mathdoc.fr/articles/10.21136/AM.1982.103981/ %R 10.21136/AM.1982.103981 %G en %F 10_21136_AM_1982_103981
[1] A. Lešanovský: Analysis of a Two-Unit Standby Redundant System with Three States of Units. Apl. mat. 27 (1982), 192-208. | MR
Cité par Sources :