Modelling and calculation of dose distribution in tissue-equivalent medium
Vestnik Sankt-Peterburgskogo universiteta. Prikladnaâ matematika, informatika, processy upravleniâ, no. 3 (2013), pp. 142-149 Cet article a éte moissonné depuis la source Math-Net.Ru

Voir la notice de l'article

The model of a radiation field generated by medical linear accelerator in a tissue-equivalent medium is suggested. This model can be applied to radiation treatment planning. A distinctive feature of the model is representation of a therapeutic beam as a set of pencil beams. Such representation allows to calculate dose distribution for a radiation field of an arbitrary form. The method of calculation and software implementation, which are based on the suggested model, are described. Software presented consists of two parts: a module for processing dosimetric information and a module for dose distribution calculation. The purpose of a dosimetric module is initializing of model for a specific accelerator. After that initialization the model can be used in a calculation module. Bibliogr. 13. Il. 6.
Keywords: radiation treatment planning system, dose distribution, intensity-modulated radiation therapy.
@article{VSPUI_2013_3_a13,
     author = {D. F. Gordeev},
     title = {Modelling and calculation of dose distribution in tissue-equivalent medium},
     journal = {Vestnik Sankt-Peterburgskogo universiteta. Prikladna\^a matematika, informatika, processy upravleni\^a},
     pages = {142--149},
     year = {2013},
     number = {3},
     language = {ru},
     url = {http://geodesic.mathdoc.fr/item/VSPUI_2013_3_a13/}
}
TY  - JOUR
AU  - D. F. Gordeev
TI  - Modelling and calculation of dose distribution in tissue-equivalent medium
JO  - Vestnik Sankt-Peterburgskogo universiteta. Prikladnaâ matematika, informatika, processy upravleniâ
PY  - 2013
SP  - 142
EP  - 149
IS  - 3
UR  - http://geodesic.mathdoc.fr/item/VSPUI_2013_3_a13/
LA  - ru
ID  - VSPUI_2013_3_a13
ER  - 
%0 Journal Article
%A D. F. Gordeev
%T Modelling and calculation of dose distribution in tissue-equivalent medium
%J Vestnik Sankt-Peterburgskogo universiteta. Prikladnaâ matematika, informatika, processy upravleniâ
%D 2013
%P 142-149
%N 3
%U http://geodesic.mathdoc.fr/item/VSPUI_2013_3_a13/
%G ru
%F VSPUI_2013_3_a13
D. F. Gordeev. Modelling and calculation of dose distribution in tissue-equivalent medium. Vestnik Sankt-Peterburgskogo universiteta. Prikladnaâ matematika, informatika, processy upravleniâ, no. 3 (2013), pp. 142-149. http://geodesic.mathdoc.fr/item/VSPUI_2013_3_a13/

[1] Elizarova M. V., Ovsyannikov D. A., Cheresmin V. M., Physics and technology aspects of radiotherapy, ucheb. posobie, Izd-vo S.-Peterb. gos. un-ta, S.-Peterburg, 2007, 184 pp.

[2] Kosunen A., Jarvinen H., Vatnitskij S. e. a., “Intercomparison of radiotherapy treatment planning systems for external photon and electron beam dose calculations”, Radiotherapy and Oncology, 29 (1993), 327–335 | DOI

[3] Saha G. P., Physics and radiobiology of nuclear medicine, Springer, New York, 2006, 254 pp.

[4] Ovsyannikov D. A., Sergeev S. L., Stuchenkov A. B., Zareckij D. V., Zhabko A. P., Vorogushin M. F., Shishov V. A., Anuchin O. M., Radiation treatment planning system (SKANPLAN), Computer program registration certificate No 2005612599, 2005

[5] Radiation treatment planning system “SKANPLAN” for linear accelerators and cobalt units, Registration certificate No FSR 2011/12824, 2011

[6] Ovsyannikov D. A., Sergeev S. L., Stuchenkov A. B., Shishov V. A., “SKANPLAN: radiation treatment planning system for medical accelerators”, Vestnik S.-Peterb. un-ta, ser. 10: prikladnaja matematika, informatika, processy upravleniya, 2009, no. 4, 34–37

[7] Kanaev S. V., Shishov V. A., “The modern technologies in radiation oncology”, Prakticheskaya Onkologiya, 6:1 (2005), 18–25

[8] Bourland J. D., Chaney E. L., “A finite-size pencil beam model for photon dose calculation in three dimensions”, Med. Phys., 19 (1992), 1401–1413 | DOI

[9] Jelen U., Sohn M., Alber M., “A finite size pencil beam for IMRT dose optimization”, Phys. Med. Biol., 50 (2005), 1747–1766 | DOI

[10] Knoos T., Ceberg C., Weber L., Nilsson P., “The dosimetric verification of a pencil beam based treatment planning system”, Phys. Med. Biol., 39 (1994), 1609–1628 | DOI

[11] Lin H., Wu Y. C., Chen Y. X., “A finite size pencil beam for IMRT dose optimization — a simpler analytical function for the finite size pencil beam kernel”, Phys. Med. Biol., 51 (2006), L13–L15 | DOI

[12] Ostapiak O. Z., Zhu Y., Van Dyk J., “Refinements of the finite-size pencil beam model of three-dimensional photon dose calculation”, Med. Phys., 24 (1997), 743–750 | DOI

[13] Gordeev D. F., “Processing of dosimetric information for initialization of radiation treatment planning system SKANPLAN”, Protsessi upravleniya i ustoychivost', Trudy 43-ey mezhdunarodnoy nauchnoy konferencii aspirantov i studentov, eds. A. S. Eremin, N. V. Smirnov, Izdat. Dom S. Peterb. gos. un-ta, S.-Peterburg, 2012, 277–282