Mots-clés : preamplifier
@article{UZKU_2018_160_4_a2,
author = {A. S. Alexandrov and M. M. Doroginizkii and M. S. Tagirov and V. D. Skirda},
title = {Towards possible application of quantum magnetometers in nuclear magnetic logging tools},
journal = {U\v{c}\"enye zapiski Kazanskogo universiteta. Seri\^a Fiziko-matemati\v{c}eskie nauki},
pages = {631--643},
year = {2018},
volume = {160},
number = {4},
language = {ru},
url = {http://geodesic.mathdoc.fr/item/UZKU_2018_160_4_a2/}
}
TY - JOUR AU - A. S. Alexandrov AU - M. M. Doroginizkii AU - M. S. Tagirov AU - V. D. Skirda TI - Towards possible application of quantum magnetometers in nuclear magnetic logging tools JO - Učënye zapiski Kazanskogo universiteta. Seriâ Fiziko-matematičeskie nauki PY - 2018 SP - 631 EP - 643 VL - 160 IS - 4 UR - http://geodesic.mathdoc.fr/item/UZKU_2018_160_4_a2/ LA - ru ID - UZKU_2018_160_4_a2 ER -
%0 Journal Article %A A. S. Alexandrov %A M. M. Doroginizkii %A M. S. Tagirov %A V. D. Skirda %T Towards possible application of quantum magnetometers in nuclear magnetic logging tools %J Učënye zapiski Kazanskogo universiteta. Seriâ Fiziko-matematičeskie nauki %D 2018 %P 631-643 %V 160 %N 4 %U http://geodesic.mathdoc.fr/item/UZKU_2018_160_4_a2/ %G ru %F UZKU_2018_160_4_a2
A. S. Alexandrov; M. M. Doroginizkii; M. S. Tagirov; V. D. Skirda. Towards possible application of quantum magnetometers in nuclear magnetic logging tools. Učënye zapiski Kazanskogo universiteta. Seriâ Fiziko-matematičeskie nauki, Uchenye Zapiski Kazanskogo Universiteta. Seriya Fiziko-Matematicheskie Nauki, Tome 160 (2018) no. 4, pp. 631-643. http://geodesic.mathdoc.fr/item/UZKU_2018_160_4_a2/
[1] Casanova F., Perlo J., Blumich B. (eds.), Single-sided NMR, Springer, Berlin–Heidelberg, 2011, 1–10
[2] Fedotov V. V., Litvinov Yu. S., Nesterova Zh. Yu., Fedotov A. V., Antenna system for detecting nuclear resonance excluding effect of induced interference and transient processes, Patent RF No 2376588 S2. Byull. No 28, 2009, 3 pp. (In Russian)
[3] Clarke J., Braginski A. I., The SQUID Handbook, v. I, Fundamentals and technology of SQUIDs and SQUID systems, Wiley-VCH, Weinheim, 2004, 409 pp.
[4] Greenberg Ya. S., “Application of superconducting quantum interference devices to nuclear magnetic resonance”, Rev. Mod. Phys., 70:1 (1998), 175–222 | DOI
[5] Dantsker E., Clarke J., Patent US 023161 A. Low-noise SQUID, Apl. No 09/032171; Filed Feb. 27, 1998.; Pud. Date: Feb. 8, 2000 | Zbl
[6] Penanen K. I., Eom B. H., Hahn I., Patent US 2011/0210738 A1. Low field SQUID MRI devices, components and methods, Appl. No 13/090931, Filed: Apr. 20, 2011, Pub. Date: Sep. 1, 2011
[7] Tesche C. D., Clarke J., “dc SQUID: Noise and optimization”, J. Low Temp. Phys., 29:3–4 (1977), 301–331 | DOI
[8] Augustine M. P., TonThat D. M., Clarke J., “SQUID detected NMR and NQR”, Solid State Nucl. Magn. Reson., 11:1–2 (1998), 139–156 | DOI
[9] Suzuki H., Higashino Y., Ohtsuka T., “SQUID NMR Studies of TmPO4”, J. Low Temp. Phys., 41:5–6 (1980), 449–461 | DOI
[10] Meredith D. J., Pickett G. R., Symko O. G., “Application of a SQUID Magnetometer to NMR at Low Temperatures”, J. Low Temp. Phys., 13:5–6 (1973), 607–615 | DOI
[11] Clarke J., “SQUIDS: Theory and Practice”, The New Superconducting Electronics, eds. Weinstock H., Ralston R. W., Springer, Dordrecht, 1993, 123–180 | DOI
[12] Webb R. A., “New technique for improved low-temperature SQUID NMR measurements”, Rev. Sci. Instrum., 48:12 (1977), 1585–1594 | DOI
[13] Chamberlin R. V., Moberly L. A., Symko O. G., “High-sensitivity magnetic resonance by SQUID detection”, J. Low Temp. Phys., 35:3–4 (1979), 337–347 | DOI
[14] Vinegar H. J., Patent US 4987368. Nuclear magnetism logging tool using high-temperature superconducting SQUID detectors, Appl. No 403042, Filed: Aug. 31, 1989, Pub. Date: Jan. 22, 1991
[15] Loren J. D., Robinson J. D., “Relations between pore size fluid and matrix properties, and NML measurements”, SPE J., 10:3 (1970), 268–278 | DOI
[16] Day E. P., “Detection of NMR using a Josephson-junction magnetometer”, Phys. Rev. Lett., 29:9 (1972), 540–542 | DOI
[17] Meredith D. J., Pickett G. R., Symko O. G., “Detection of NMR at low temperatures using a superconductive quantum interference device”, Phys. Lett. A, 42:1 (1972), 13–14 | DOI
[18] Hirschkoff E. C., Symko O. G., Vant-Hull L. L., Wheatly J. C., “Observation of the static nuclear magnetism of pure metallic copper in low magnetic fields”, J. Low Temp. Phys., 2:5–6 (1970), 653–665 | DOI
[19] Bishop J. H., Hirschkoff E. C., Wheatley J. C., “Very-low-temperature static magnetic properties of certain metals possibly useful as magnetic thermometers”, J. Low Temp. Phys., 5:6 (1971), 607–616 | DOI
[20] Silver A. H., Zimmerman J. E., “Quantum states and transitions in weakly connected superconducting rings”, Phys. Rev., 157:2 (1967), 317–341 | DOI
[21] Pickens K. S., Bolef D. I., Holland M. R., Sundfors R. K., “Superconducting quantum interference device detection of acoustic nuclear quadrupole resonance of Sb121 and Sb123 in antimony metal”, Phys. Rev. V, 30:1 (1984), 3644–3648 | DOI
[22] Fan N. Q., Clarke J., “Low-frequency nuclear magnetic resonance and nuclear quadrupole resonance spectrometer based on a dc superconducting quantum interference device”, Rev. Sci. Instrum., 62:6 (1991), 1453–1459 | DOI
[23] Hurlimann M. D., Pennington C. H., Fan N. Q., Clarke J., Pines A., Hahn E. L., “Pulsed Fourier-transform NQR of 14N with a dc SQUID”, Phys. Rev. Lett., 69:4 (1992), 684–687 | DOI
[24] Thomasson S. L., Gould C. M., “High slew rate bandwidth integrated dc SQUID magnetometer for NMR applications”, IEEE Trans. Appl. Supercond., 5:2 (1995), 3222–3225 | DOI
[25] Seton H. C., Bussell D. M., Hutchinson J. M. S., Nicholson I., Lurie D. J., “DC SQUID based NMR detection from room temperature samples”, Phys. Med. Biol., 37:11 (1992), 2133–2138 | DOI
[26] Kumar S., Thorson B. D., Avrin W. F., “Broadband SQUID NMR with room-temperature samples”, J. Magn. Reson. Ser. B, 107:3 (1995), 252–259 | DOI | MR
[27] Kumar S., Avrin W. F., Whitecotton B. R., “NMR of room temperature samples with a flux-locked dc SQUID”, IEEE Trans. Magn., 32:6 (1996), 5261–5264 | DOI
[28] Li J., Lusher C. P., Digby M. E., Cowan B., Saunders J., Drung D., Schurig T., “DC SQUID spectrometers for NMR”, J. Low Temp. Phys., 110:1–2 (1998), 261–267 | DOI
[29] Körber R., Casey A., Shibahara A., Piscitelli M., Cowan B. P., Lusher C. P., Saunders J., Drung D., Schurig Th., “Nuclear magnetic resonance on room temperature samples in nanotesla fields using a two-stage dc superconducting quantum interference device sensor”, Appl. Phys. Lett., 91:14 (2007), 142501, 1–3 | DOI