@article{SEMR_2024_21_1_a34,
author = {I. G. Kazantsev and A. K. Tankibayeva and S. K. Kumargazhanova and B. N. Azamatov},
title = {Correction of intensity inhomogeneity in magnetic resonance images using ramp filter},
journal = {Sibirskie \`elektronnye matemati\v{c}eskie izvesti\^a},
pages = {307--314},
year = {2024},
volume = {21},
number = {1},
language = {en},
url = {http://geodesic.mathdoc.fr/item/SEMR_2024_21_1_a34/}
}
TY - JOUR AU - I. G. Kazantsev AU - A. K. Tankibayeva AU - S. K. Kumargazhanova AU - B. N. Azamatov TI - Correction of intensity inhomogeneity in magnetic resonance images using ramp filter JO - Sibirskie èlektronnye matematičeskie izvestiâ PY - 2024 SP - 307 EP - 314 VL - 21 IS - 1 UR - http://geodesic.mathdoc.fr/item/SEMR_2024_21_1_a34/ LA - en ID - SEMR_2024_21_1_a34 ER -
%0 Journal Article %A I. G. Kazantsev %A A. K. Tankibayeva %A S. K. Kumargazhanova %A B. N. Azamatov %T Correction of intensity inhomogeneity in magnetic resonance images using ramp filter %J Sibirskie èlektronnye matematičeskie izvestiâ %D 2024 %P 307-314 %V 21 %N 1 %U http://geodesic.mathdoc.fr/item/SEMR_2024_21_1_a34/ %G en %F SEMR_2024_21_1_a34
I. G. Kazantsev; A. K. Tankibayeva; S. K. Kumargazhanova; B. N. Azamatov. Correction of intensity inhomogeneity in magnetic resonance images using ramp filter. Sibirskie èlektronnye matematičeskie izvestiâ, Tome 21 (2024) no. 1, pp. 307-314. http://geodesic.mathdoc.fr/item/SEMR_2024_21_1_a34/
[1] G. Mohan, M.M. Subashini, “MRI based medical image analysis: Survey on brain tumor grade classification”, Biomedical Signal Processing and Control, 39 (2018), 139–161 | DOI | MR
[2] U. Vovk, F. Pernus, B. Likar, “A Review of methods for correction of intensity inhomogeneity in MRI”, IEEE Transactions on Medical Imaging, 26:3 (2007), 405–421 | DOI
[3] M. Doneva, “Mathematical models for magnetic resonance imaging reconstruction: An overview of the approaches, problems, and future research areas”, IEEE Signal Processing Magazine, 37:1 (2020), 24–32 | DOI
[4] C. Li, J.C. Gore, C. Davatzikos, “Multiplicative intrinsic component optimization (MICO) for MRI bias field estimation and tissue segmentation”, Magnetic resonance imaging, 32:7 (2014), 913–923 | DOI
[5] A. Banerjee, P. Maji, “Rough sets and stomped normal distribution for simultaneous segmentation and bias field correction in brain mr images”, IEEE Transactions on Image Processing, 24:12 (2015), 5764–5776 https://ieeexplore.ieee.org/document/7294696 | DOI | MR
[6] Y. Xu, S. Hu, Y. Du, “Bias correction of multiple MRI images based on an improved nonparametric maximum likelihood method”, IEEE Access, 7 (2019), 166762–166775 | DOI
[7] Y. Wei, G. Wang, J. Hsieh, “An intuitive discussion on the ideal ramp filter in computed tomography I”, Comput. Math. Appl., 49:5-6 (2005), 731–740 | DOI | MR | Zbl
[8] F. Khellaf, N. Krah, J.M. Litang, S. Rit, “2D directional ramp filter”, Phys. Med. Biol., 65:8 (2020), 08NT01 | DOI
[9] Hong Yan edt., Signal processing for magnetic resonance imaging and spectroscopy, Marcel Dekker, Inc., New York–Basel, 2002 | DOI
[10] Y. Jiang, J. Zhao, X. Hu, J. Zou, “A Generalized Construction Model for CT Projection-Wise Filters on the SDBP Technique”, Mathematics, 10:4 (2022), 579 | DOI