Comparison and calibration of different electroporation models. Application to rabbit livers experiments
ESAIM. Proceedings, Tome 67 (2020), pp. 242-260.

Voir la notice de l'article provenant de la source EDP Sciences

Electroporation is a complex phenomenon that occurs when biological tissues are subjected to electric pulses. The clinical interest for the phenomenon has constantly increased for the last decades. Indeed, electroporation makes it possible to either kill directly the cells in the target region (tumor) or to introduce molecules into living cells. However, one of the main limitation of using electroporation in the clinical routine comes from the technical difficulties raised by such therapies, in particular it is difficult to well determine the treated zone. Numerical modeling of the electric field magnitude could provide a powerful strategy to assess the treatment efficacy: thanks to well-designed models, the computation of the distribution of the electric field is achievable, providing a numerical evaluation of the treatment. The main objective of this work is to go further on the patient-adapted numerical modeling of the electric field magnitude by laying the ground of the possible electroporation models - which will be compared qualitatively - and their calibrations. This will be done in the framework of bioelectrical measurements on rabbit livers that come from the literature.
DOI : 10.1051/proc/202067014

Gaspard Jankowiak 1 ; Cécile Taing 2, 3 ; Clair Poignard 2, 3 ; Annabelle Collin 4, 2, 3

1 RICAM - Austrian Academy of Sciences, Postgasse 7-9, 1170, Wien, Austria
2 Univ. Bordeaux, IMB, UMR 5251, F-33400, Talence, France
3 INRIA Bordeaux-Sud-Ouest, F-33400, Talence, France
4 Bordeaux INP, IMB, UMR 5251, F-33400, Talence, France
@article{EP_2020_67_a14,
     author = {Gaspard Jankowiak and C\'ecile Taing and Clair Poignard and Annabelle Collin},
     title = {Comparison and calibration of different electroporation models. {Application} to rabbit livers experiments},
     journal = {ESAIM. Proceedings},
     pages = {242--260},
     publisher = {mathdoc},
     volume = {67},
     year = {2020},
     doi = {10.1051/proc/202067014},
     language = {en},
     url = {http://geodesic.mathdoc.fr/articles/10.1051/proc/202067014/}
}
TY  - JOUR
AU  - Gaspard Jankowiak
AU  - Cécile Taing
AU  - Clair Poignard
AU  - Annabelle Collin
TI  - Comparison and calibration of different electroporation models. Application to rabbit livers experiments
JO  - ESAIM. Proceedings
PY  - 2020
SP  - 242
EP  - 260
VL  - 67
PB  - mathdoc
UR  - http://geodesic.mathdoc.fr/articles/10.1051/proc/202067014/
DO  - 10.1051/proc/202067014
LA  - en
ID  - EP_2020_67_a14
ER  - 
%0 Journal Article
%A Gaspard Jankowiak
%A Cécile Taing
%A Clair Poignard
%A Annabelle Collin
%T Comparison and calibration of different electroporation models. Application to rabbit livers experiments
%J ESAIM. Proceedings
%D 2020
%P 242-260
%V 67
%I mathdoc
%U http://geodesic.mathdoc.fr/articles/10.1051/proc/202067014/
%R 10.1051/proc/202067014
%G en
%F EP_2020_67_a14
Gaspard Jankowiak; Cécile Taing; Clair Poignard; Annabelle Collin. Comparison and calibration of different electroporation models. Application to rabbit livers experiments. ESAIM. Proceedings, Tome 67 (2020), pp. 242-260. doi : 10.1051/proc/202067014. http://geodesic.mathdoc.fr/articles/10.1051/proc/202067014/

Cité par Sources :